Gas safety management in confined spaces (Using UA-58)

Thank you for purchasing DEKIST UA-58.

UA-58 is a Radionode device with USB output. The UA-58 device consists of a channel that converts the analog signal of an external sensor into a digital signal and a USB that sends the digitized value of the channel. UA-58 is a very useful product that supports various operating systems using the USB CDC protocol.

1. RN17X + UA-58 connection

RN171 PoE power supply method / Separate power supply method using RN172 USB extension cable

The RN171 supplies power through the PoE function, and the RN172 can supply power separately by connecting the sensor with a USB extension cable.

2. Gas sensor alarm automatic setting function

RN17X + UA-58 gas sensor alarm range

The RN17X + UA-58 product automatically recognizes UA-58 and sets the alarm without having to set the alarm range by setting the gas hazard standard value at the radio node.

Buzzer Alarm: On
1CH(CO) [0.00 ~ 30.00] / 2CH(O2) [18.00 ~ 25.00]
3CH(H2S) [0.00 ~ 5.00] / 4CH(CO2) [0.00 ~ 5000.00]

It is set automatically like this, and it is set according to the user's standard
You can set the alarm range. If the alarm is out of range, the buzzer of the RN17X will sound.

3. QR Code APP utilization and data view function within Radionode365
Check gas concentration in confined space using QR Code

Radionode365 provides a function to quickly and easily view product data with QR Code. In the data view, it is a function that provides sensor data in the form of graphs and tables, and data can be stacked.

Scan the right QR Code and click the link

It is used so that workers can enter the work site after checking the gas level after scanning the QR Code before entering the work site.

*For detailed settings Radionode365 - data outputPlease check in.